Load USB Configuration Files

This page will list the steps required to load the Cyberware USB configuration files into the scanner's EEPROM.

  1. Navigate to the '...\Program Files\Cyberware\CyScanÏgu\' folder using Windows Explorer.
  2. Rename any existing files in the '...\Program Files\Cyberware\CyScanÏgu\' folder to prevent an accidental overwrite.
  3. Copy any files given to you by Cyberware support into the '...\Program Files\Cyberware\CyScanÏgu\' folder.
  4. For each device that requires a configuration update, follow this procedure:
    1. Choose Scanner | Select Device...
    2. Determine which device you wish to modify. An overview of some of the devices is listed here:
    3. Device NameDevice Type
      umMotion Controller (629)
      uMotion Controller (629) - Sperical Gantry
      urRange Sensor (CCD)
      utTexture Sensor (S-RGB)
      ucDCS Color Sensor
      udDRS Range Sensor
      ud0DRS Range Sensor 0
      ud1DRS Range Sensor 1
      ud2DRS Range Sensor 2
      ud3DRS Range Sensor 3
    4. Click on the desired device one time.
    5. Press the Properties... button.
    6. Choose the Configure... button. The EEPROM Editor window should now open.
    7. Click the Clear Cfg button in the EEPROM Editor window.
    8. Press the Open Cfg... button in the EEPROM Editor window.
    9. A dialog will open asking to "Open NEW FACTORY configuration USB file." Click the No button.
    10. Another dialog Will open and ask if you would like to "Open EXISTING SAVED configuration USB file." Click the Yes button.
    11. A file browswer should now appear on your screen. Navigate to the plain text configuration file, in the '...\Cyberware\CyScanÏgu\' folder. Select file and click Open.
    12. In the EEPROM Editor window, press the Accept button.
  5. Exit CyScan.